6. Practical Use
Step 3:
Select the program
Press the [Fully Automatic Press Function].
Step 4:
Load the furnace and start the program
Load the furnace with the preheated investment ring.
Now press the START button and the program will be started.
The LED lights up in green.
The progress of the program in shown in the display.
The furnace head opens automatically at the end of the program.
Press time and press distance are indicated in the results panel.
After acknowledging the results panel and as soon as the OSD lights
up in green, the furnace is ready for the next program start.