Part No. 2718-55-16
OPERATION MANUAL
© 2017 IVY Biomedical Systems Inc. All Rights Reserved.
Part No. 3232-00-16 Rev.12 EN
Cardiac Trigger Monitor
Model 7600/7800
Model 7800 shown

Table of Contents

Questions and Answers

Summary

User Responsibility

Safety

Electrical Safety

Covers electrical safety for the monitor, including grounding and power connection requirements.

Explosion Hazard

Warns about explosion hazards when using the equipment in the presence of flammable anesthetics.

Patient Connections Safety

Details safe practices for connecting patients, including electrical isolation and cable routing.

Pacemaker Patient Precautions

Provides warnings for pacemaker patients regarding rate meter accuracy and surveillance.

Monitor Description

Controls and Indicators

Identifies and explains the function of the monitor's physical buttons and visual indicators.

Display Overview

Describes the information presented on the monitor's LCD screen, including ECG and heart rate.

Alarm Messages

Lists and explains various technical, patient, and reminder alarm messages.

Menu Structure

Details the hierarchical organization of the monitor's menu system for configuration.

Monitor Setup

Monitor Installation

Guides the user through the physical setup and mounting of the monitor.

Setting Up for Operation

Details the initial steps to connect and power on the monitor for use.

Setting Alarm Limits

Guides the user on setting high and low heart rate alarm thresholds.

ECG Monitoring

Safety Considerations

Highlights safety precautions related to ECG lead wires, electrodes, and electrical isolation.

Patient Connections

Provides detailed instructions for applying electrodes and connecting patient cables.

Impedance Measurement (Model 7800 Only)

Explains the impedance measurement feature for verifying skin preparation and electrode contact.

Lead Selection

Explains how to select ECG leads for the trigger and secondary waveforms.

Pacemaker Detection

Details the pacemaker detection function and associated warnings.

Alarm Limits

Instructs on how to set and adjust high and low heart rate alarm limits.

ECG Data Storage and Transfer

ECG Data Transfer Using USB (Model 7800 Only)

Describes how to save and retrieve ECG data using a USB memory stick.

Alarm Messages

Patient Alarms

Details patient alarms such as HR HIGH, HR LOW, and ASYSTOLE.

Technical Alarms

Describes technical alarms like LEAD OFF, CHECK LEAD, and SYSTEM ERROR.

Monitor Testing

Internal Test

Guides on performing the monitor's internal self-test for verification.

ECG Simulator

Explains how to use the integrated ECG simulator for testing.

Troubleshooting

Specifications

ECG Specifications

Lists detailed specifications for the ECG monitoring function.

Alarm Specifications

Lists parameters and levels for various alarm conditions.

Ivy Biomedical Systems 7800 Specifications

General IconGeneral
CategoryPatient Monitor
ECG3/5-lead, arrhythmia detection
NIBPAdult, pediatric, neonatal modes
RespirationImpedance respiration measurement
PowerAC power and battery operation
AlarmsAudible and visual alarms, adjustable alarm limits