For Your Safe Flight Page | 6
Section 2 - Interpreting Data
Operation for each Phase of Flight
(Worth adding to your run-up checklist.)
Engine Run-Up
Suggested setup:
Set engine to run-up RPM
Normalize view
Manual mode
Verify:
uniform rise of about 50°F in all EGTs in
single magneto operation.
uniform rise of EGTs with application of the
mixture control.
Be alert for:
unusually low voltage (see AFMS)
cold OIL and normal oil pressure
abnormally high CHT
large drop in EGT on one cylinder in single
magneto operationmay be fouled spark
plug.

Related product manuals