Page 16
J-400
7.0 Power Requirements
Jacuzzi
®
spas are designed to provide optimum performance and
exibility of use when connected to their maximum electrical service.
They are congured at the factory. The most common electrical
connections are listed below:
• All North American 60 Hz Models only: These models come set for
50A logic. If you prefer, your qualied technician can perform a logic
modication that allows the spas to operate on a different electrical
service, see table footnotes below. Reference page 85.
North American Models (60 Hz)
Voltage: 240 VAC/40A* 240 VAC/50A** 240 VAC/60A***
Max. Current Draw:
1-Pump System: 26A 36A N/A
2-Pump System: 26A 37A 48A
3-Pump System: N/A 37A 48A
Frequency: 60 Hz 60 Hz 60 Hz
Number of Wires: 3 3 3
*
In 40A conguration, the heater will not operate while either jets pump is
running. Not recommended for the J495.
**
In 50A conguration, the heater will operate when one jets pump is
running, but will not operate if more than one jets pump is running. This
is the factory setting.
***
In 60A conguration the heater will operate when two jets pumps are
running, but will not operate if three jets pumps is running.