Page 19
ENGLISH
Jandy
®
Pro Series JE Heat Pumps
|
Installation and Operation Manual

To enable the spa mode, press
. The associated left
green LED indicator will light and the unit will display
.
 XXX represents the current temperature setting
on the control. The default setting for spa
temperature is 102°F (38°C).
You can change the temperature set point by pressing
the
 or button.Repeatedly press the  or

button until you reach the desired temperature
set point. After 5 seconds of inactivity, the new set point
is stored in memory. When the water temperature falls
to 1 degree below the temperature setting
and after a 5
minute delay, the control will start the heat pump and
the associated right LED will light RED.

If connected to an AquaLink, the Maintain Heat mode
allows the heat pump to monitor the temperature of the
water 24 hours a day by turning the spa pump on and
sampling the water temperature.
 This feature only works when connected to
an AquaLink.
To operate in spa mode with the Maintain Heat feature,
press
, then press , press the  button
until
 is displayed, press the
 button. The associated left green LED indicator
will light and the unit will display
.Change
the temperature set point by pressing the
 or 
button until the desired set point is displayed. After
5 seconds of inactivity, the new set point is stored in
memory.
 

 The chiller is an optional equipment. Not all
units are provided with chiller.

To enable the pool mode, press
. The associated
left green LED indicator will light and the unit will
display
.
 XXX represents the current temperature setting
on the control. The default setting for pool
temperature is 80°F (26°C).
Press the  button. Press the  or  button
until you reach
, press the  button.
  will not be displayed if the unit is
not provided with chiller.
You can change the temperature set point by pressing
the
 or button.Repeatedly press the  or

button until you reach the desired temperature
set point. After 5 seconds of inactivity, the new set point
is stored in memory. When the water temperature rises
to 1 degree above the temperature setting
and after a 5
minute delay, the control will start the heat pump and
the associated right LED will light GREEN
.

If connected, the Maintain Chill option mode allows the
unit to monitor the temperature of the water 24 hours
a day by turning the pool pump on and sampling the
water temperature.
A Maintain Temp Relay is required (provided) and the
feature must be enabled.
When the temperature of the water rises above the
desired temperature setting, the control will then turn on
the unit and the associated right green LED will light.
To operate in pool mode with the Maintain Chill feature,
press
, then press , then press the 
button until
is displayed,
press the  button. The associated left green LED
indicator will light and the unit will display
.
Change the temperature set point by pressing the

or
 button until the desired set point is displayed.
After 5 seconds of inactivity, the new set point is stored
in memory.

If connected to an AquaLink, the Maintain Chill mode
allows the heat pump to monitor the temperature of the
water 24 hours a day by turning the spa pump on and
sampling the water temperature.
 This feature only works when connected to
an AquaLink.
When the water temperature rises above the
programmed temperature set point, the control will start
the heat pump.
To operate in the spa mode with the Maintain Chill
feature, press
, then press , press the 
button until
is displayed,
press the
 button. The associated left green LED
indicator will light and the unit will display
.
Change the temperature set point by pressing the

or
 button until the desired set point is reached.
After 5 seconds of inactivity, the new set point is stored
in memory.