Pro Series VS PlusHP Pumps
|
Installation & Operation Manual
Symptom Possible Cause/Solution
Variable-Speed
Controller LCD
is not displaying
information
or
pump LEDs are
not illuminated.
Incorrect dip switch setting.
Make sure pump dip switches 1 and 2 are both ON if the controller is the JEP-R and both are OFF if the
controllerisaPDA,AquaLinkRS,orAquaLinkZ4.See“3.2.4.1 Install with AquaLink® controller”
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See “3.2 Electrical Installation”
Controller
displays “Pump
not connected”.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See “3.2 Electrical Installation”
Improper pump address set.
Ensure pump dip switches 3 and 4 are set properly for the installation. Both should be OFF for use with
Variable-SpeedControllerorsettotheproperaddresswhenconnectedtoanAquaLink
RS,AquaLinkPDA,
oranAquaLinkZ4.See“3.2.4.1 Install with AquaLink® controller”
Fault message
appears on
controller display.
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure how to correct fault, contact
ZodiacTechnicalSupportat800.822.7933.