EasyManuals Logo

Jandy Versa-Plumb CL Series User Manual

Jandy Versa-Plumb CL Series
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Page 9
Figure 7. Sweep Elbow
Note: Do not
overtighten.
LXi Heater
CV Filter
SHP
Pump
Sweep Elbow
P/N SEAQL1001
Sweep Elbow
P/N SEFL1002
7½”
Minimum
Figure 8. LXi Heater, CV Filter and SHP Pump Sweep Elbow Installation
Cartridge Pool Filters - CL and CV Series Filters
b. Be sure there is a minimum distance of
7½ inches between the center of the pump
RXWOHWSRUWDQGWKH¿OWHULQOHWEXONKHDGWR
accommodate the sweep elbow(s). See
Figure 8 for recommended installation
FRQ¿JXUDWLRQ
NOTE The SHP pump shown in Figure 8 is for reference
only. The Jandy sweep elbow also works with the
MHP and PHP series pumps.
127( %HVXUHWRXVHRUòVFKHGXOH39&SLSH
c. Clean the cut ends of the pipe and both ends
of the sweep elbow(s) with an appropriate
NSF
®
DSSURYHG$OO3XUSRVHFOHDQHUSULPHU
Glue the sweep elbow(s) onto the cut pipe
ends using an appropriate All Purpose NSF
®
DSSURYHGDGKHVLYHJOXH
127( -DQG\UHFRPPHQGV:HOG2Q39&WR&39&
&HPHQWWRJOXH6FKHGXOH39&
d. After the glue is cured, close the pressure
UHOLHIYDOYHRQWRSRIWKH¿OWHUVWDUWWKH
V\VWHPDQGFKHFNIRUSURSHUZDWHUÀRZ
6. Make all plumbing connections in accordance
with local plumbing and building codes. Filter
connections are provided with an o-ring seal. To
avoid damage to the o-rings, use only a silicone
base lubricant on the o-rings. Do not use pipe joint
compound, glue or solvent on inlet/outlet union
coupling nuts.
7. Keep piping tight and free of leaks. Pump suction
OLQHOHDNVPD\FDXVHDLUWREHHQWUDSSHGLQ¿OWHU
tank or loss of prime at the pump. Pump discharge
line leaks may show up as dampness or jets of
water.
 6XSSRUWWKHLQOHWRXWOHWSLSHVLQGHSHQGHQWO\WR
SUHYHQWDQ\XQGXHVWUDLQVRQWKH¿OWHUYDOYH
9. Connect the pipes using the unions supplied with
WKH¿OWHU'RQRWXVH7HÀRQWDSHRUSLSHGRSHRQ
any unions. Assemble the unions dry and hand
tighten. See Figure 6.
 ,IGHVLUHGWKH&9¿OWHUGUDLQFDQEHSOXPEHG
using a Jandy universal union. The plumbing must
contain a ball valve as shown in Figure 6.
CAUTION
Be sure that all provisions for wastewater disposal
meet local, state or national codes. During any
draining process, one hundred gallons (100 gals.)
or more of pool water will be discharged. CL and CV
(Cartridge) Filters are not subject to backwashing. Do
not discharge water where it will cause flooding or
damage.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy Versa-Plumb CL Series and is the answer not in the manual?

Jandy Versa-Plumb CL Series Specifications

General IconGeneral
BrandJandy
ModelVersa-Plumb CL Series
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals