EasyManua.ls Logo

janitza optec UMG-96 User Manual

janitza optec UMG-96
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.janitza.com
Doc No. 1.021.020.k
Doc No. 1.021.020.k
Janitza electronics GmbH
Vor dem Polsck 1
D-35633 Lahnau
Support Tel. +49 6441 9642-22
Fax +49 6441 9642-30
e-mail: info@janitza.com
Internet: http://www.janitza.com
w
K
ey 2
M
Universal Measuring Device
UMG 96
Operating instructions
Brief instructions see last page
D
L
1-N / L1-L2
L2-N / L2-L3
L3-N / L3-L1
Maximum value
P
P
rogramming mode
Sum measurement
Phase to phase
Password
Voltage transformer
Current transformer
Output K1
Output K2
M
ean value
S
Key 1 Key 2
M
SupplyMinimum
value
L
Question and Answer IconNeed help?

Do you have a question about the janitza optec UMG-96 and is the answer not in the manual?

janitza optec UMG-96 Specifications

General IconGeneral
Operating Temperature-10°C to +55°C
HarmonicsYes
Communication InterfacesRS-485, Ethernet
DisplayGraphic LCD
AccuracyClass 0.5S (IEC 62053-22)
Measurement CategoryCAT III 600V
Storage Temperature+70°C
Dimensions96 x 96 mm
Power MeasurementActive, Reactive, Apparent Power
Energy MeasurementActive, Reactive, Apparent Energy

Summary

Product description

Functional description

Explains how the UMG96 measures and processes electrical magnitudes.

Installation

Measurement and supply voltage

Details connection requirements for measurement and supply voltages.

Connection diagrams

Installation and putting into service

Connect measurement and supply voltage

Details how to connect measurement and supply voltages, including voltage varieties.

Program current and voltage transformers

Explains the need to program transformer ratios for accurate measurements.

Connect current transformers

Guides on connecting current transformers to the device terminals.

Check phase assignment

Removal of errors

Usage and display

Programming mode

Key functions

Password

Current transformer

Voltage transformer

Programming

Explains how to program the voltage transformer settings.

Outputs K1 and K2

Usage as switching output

Programming as switching output

Details the programming steps for configuring switching output parameters.

Usage as pulse output

Programming as pulse output

Guides on programming the pulse output, including pulse valency.

Pulse valency

Minimum pulse width

Averaging times (Bimetal function)

User password

Indicating range and accuracy

Configuration data

Technical data