Notice regarding Installation of the Electro Press
When you install the Electro Press,
especially when mounting it on an automatic machine,
please be sure to follow the instructions below.
z Be sure to ground the Electro Press and other equipment securely. Keep grounding
resistance impedance as low as possible.
z
Use the shield for the I/O cable and make the wiring length as short as possible. Ground the
shield of the I/O cable.
z Wire the power supply cord separately from the I/O cable. Never bundle the power supply
cord and the I/O cable together.
z The wiring between the electric power system and the signal system in the distribution panel
should be isolated.
z Do not place or install any equipment emitting electric noise near the Electro Press. Use a
power source that supplies stable power.
Do not plug multiple cables into one electrical
outlet.
z
The load cell at the end of the ram should be periodically checked and, if necessary,
calibrated. When you install the Electro Press, leave enough space to allow load cell
calibration (for example by making the jigs under the ram detachable.)
z
Leave space between the Electro Press and wall or any other obstacle so that you can
remove the cover with a screwdriver when it is necessary to repair the unit. Also, leave
sufficient space at the side for the cooling fan to cool the unit.
z After completing the wiring of the Electro Press, confirm the wiring status using the following
procedure.
1. Select [Diagnosis Mode] from the maintenance mode menu.
2. Select [External I/O Diagnosis.]
IMPORTANT: For your safety, never disassemble or modify the Electro Press.
We are not liable for injury or damage caused by a modified Electro Press.
Switch Box
We suggest that you use our standard switch box (optional for the unit type.) If you use a
different switch box, be sure to use a shield wire in addition to the I/O cable.
If you want the switch box to be detached, state your request on the order sheet. We will equip
the Electro Press with a connector for the switch box at the rear of the unit.