EasyManua.ls Logo

JCM EBA-34-SD3 - Page 7

Default Icon
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 - 7
CHAPTER 1 Product Name & Specifications
5-10 Power Supply Voltage 12 VDC ± 5% (EBA-30/31/32/33/34/35)
(Use a power supply with 3A or higher capacity.)
24VDC ± 10% (EBA-34/35)
(Use a power supply with 1.6A or higher capacity.)
5-11 Current Consumption 12VDC
(1) In standby: 0.3A
(2) During operation: 1.6A (3A max.)
24VDC
(1) In standby: 0.2A
(2) During operation: 0.9A (1.6A max.)
5-12 Operating Environment (1) Operating temperature: 5 to 50C
(2) Storing temperature: -20 to 60C
(3) Relative humidity: 30 to 85% (no condensation)
(4) Installation: Install the unit indoors where it is not exposed to direct
sunlight.
5-13 Outer Dimensions Refer to the outline drawings for the configuration with SD3 stacker,
and without the stacker.
5-14 Weight (1) With SD3 stacker Approx. 2.5 kg
(2) Without SD3 stacker Approx. 1.0 kg
5-15 Mounting Horizontal mounting
Earthe the the sheet metal part of the unit
[NOTE] Unless otherwise specified, the general specifications of the EBA-3x series are measured
based on the following conditions:
(1) Power supply voltage: 12 VDC ± 0.1 V (19.9 to 12.1 V)
24VDC ± 0.2 V (23.8 to 24.2V)
(2) Temperature: 25
C ± 3
C (22 to 28
C)
(3) Relative humidity 40 to 65%
(4) Standard bill 20 Euro bill

Related product manuals