NIGHT TIME
DELAY START
OPERATION
SAMPLE ONE STAGE PROGRAM
(Tobecompletedandreadytocastin24hours)
HEAT RATE
TEMP
HOLD TIME
STAGE 1
STAGE 2
STAGE 3
STAGE 4
24:00
10°F(6°C)
1600°F(871°C)
1:00
NO
NO
NO
*
*
*
*
*
*
*Thoughanynumbermayappear,theunitisdeactivatedwhen“NO”isselectedfortheHEATRATE
NOTE: To turn off STAGE 2,3 and 4, select “NO” for the HEAT RATE in STAGE 2.
PressNIGHTTIME(DELAYSTART)Infinityautomaticallyturnsonatthecorrecttimetocompletetheprogram
andbereadytocastin24hours
SAMPLE TWO STAGE PROGRAM
(Tostartimmediately)
HEAT RATE
TEMP
HOLD TIME
STAGE 1
STAGE 2
STAGE 3
STAGE 4
10°F(6°C)
1600°F(871°C)
1:00
NO
NO
*
*
*
*
*Thoughanynumbermayappear,theunitisdeactivatedwhen“NO”isselectedfortheHEATRATE
20°F(11°C)
600°F(316°C)
30
NOTE: To turn off STAGE 3 & 4, select “NO” for the HEAT RATE in STAGE 3.
Tostartimmediately,pressSTART/STOP
Followthesameprogrammingproceduresifathreeorfourstageprogramisdesired
15