SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
6-20 31217162
Engine Coolant
Lube Point - Fill Cap/Fill Level
Interval - Check coolant level daily. Ensure it is between
the FULL and LOW lines. If coolant level is low, allow fluid
to cool, then add as required. Replace coolant annually in
accordance with engine manual.
Air Filter
Lube Points - Replaceable primary filter element (dry type)
Interval - Every 6 months or 300 hours of operation. Under
severe operating conditions (such as a very dusty work
area) check condition of filter more often.
Once a week, squeeze the evacuator valve on bottom of
air cleaner assembly to allow collected debris to fall out of
the air cleaner.
OAD02430
OAD02440

Table of Contents