68
introduction to each setting item.
8.3.2.1 Setting of regular stop time
This setting item is used to set the fixed stop time of the inverter, which is
convenient for users to set according to their needs and make the inverter stop
itself within the set time.
Table 8-9 Description of regular downtime setting
Timed
shutdown
information
Description
Note
Time
The inverter will stop automatically in minutes
after reaching this time ( Minutes)
8.3.2.2 DSP parameter setting
Used for setting key parameters of solar pump inverter system.
Table 8-10 DESCRIPTION of DSP parameter setting
DSP
Parameter
Setting
Information
Description
Note
U-Rated
Rated voltage of motor, unit is V. The setting
principle is that the rated voltage is equal to the
rated voltage indicated on the pump nameplate.
Im-Rate
Motor rated current value, unit A. The setting
principle is that the rated current is equal to the
rated current value indicated on the pump
nameplate.