86
down, this
situation is not
malfunction.
State 106
Array
over-voltage
When the
inverter
stops, the
system can
start itself
after the fault
disappears.
The input
voltage of
dc side of
inverter is
higher than
the
maximum
input
voltage of
inverter
Check the
photovoltaic array
maximum output
open circuit
voltage to ensure
that this voltage
value is lower than
the inverter
maximum input
voltage.
State 107
Array flow
When the
inverter
stops, the
system can
start itself
after the fault
disappears.
The inverter
hardware
circuit is
damaged.
Please contact
Supplier
Technology LTD.
State108
Inverse
current
overcurrent
1. When the
inverter
stops, the
system can
start itself
The power
of pump
motor is
greater than
the rated
1, check whether
the pump motor
power
More than the
rated power of the