89
or
damaged.
State 114
Overflow
alarm
Inverter shut
down until
the water
level recover
or protection
recover time
is up, the
machine will
restart
automatically.
Water level
in container
higher than
high-end
level
sensor.
If this situation
appears more than
once, please
check onsite and
set the water level
sensor at a proper
height.
State 115
The output
phase
When the
inverter
stops, the
system can
start itself
after the fault
disappears.
One or two
phase
output cable
of the
inverter is
not well
connected
to the
motor.
Please check
whether the
connection part of
three-phase output
line is reliable.