91
hardware
failure;
Fault205
The grid is
overcurrent
When the
inverter
stops, the
system can
start itself
after the
shutdown
state
disappears.
1. Short
circuit or
blocked turn
of the pump;
2. Hardware
failure
1. Check the
wiring of the
water pump and
whether the
water pump can
work normally;
2. Check whether
the output of the
inverter is
normal.
Fault206
Bus voltage
undervoltage
When the
inverter
stops, the
system can
start itself
after the
shutdown
state
disappears.
The grid
voltage is too
low, or the
array voltage
is too low, or
the hardware
fails.
Disconnect the
power grid and
photovoltaic input
switch to ensure
no voltage input
to the inverter.
Check the power
grid voltage and
photovoltaic
voltage with a
multimeter
respectively.