236
Setting Parameters
* = Factory adjusted mode
Starting the mesuring run by closing the
wheel gua
rd
Off = Start via START key
On* = Start via wheel guard
The selected mode of operation can be
transferred to the permanent memory.
Automatic braking when the wheel guard
is raised
Off = No braking
Note
When the guard is lifted, the wheel is not braked
and continues to rotate from inertia
Make sure that the wheel is not blocked by a tool or
similar item.
WEAR SAFETY GOGGLES AND TIGHTLY FITTING
WORKING CLOTHES.
On* = Braking
The selected mode of operation can be
transferred to the permanent memory.
Adjusting the DATE/TIME COUNTERS
After selecting the “Date adjustment”, in the SETTINGS
screen, a keyboard is displayed with the data entry
eld.
Enter the date as follows;
Year / Month / Day (yyyy/mm/dd).
Note:
A different structure set by the operator does not
affect the setting sequence.
After selecting the Time adjustment”, in the SETTINGS
screen, a keyboard is displayed with the data entry
eld.
Enter the time as follows;
Hours / Minutes.
Note
Changes to the date and time are immediately
activeand are retained when the machine is
next startedwithout needing to be saved to the
permanentmemory.
..