56
E360
At least one Camera calibration required
Possible causes:
the Cameras controller board has been replaced:
• the camera controller board has been
replaced
• at least one Camera has been replaced
• the calibration data is missing
• the Camera cables have been swapped
Call technical support for the following corrective
actions:
• check the connections
• calibration procedure (C122) is required to
calibrate the actual position of the Cameras
with respect to the balancer reference plane.
E361
A Camera not present or not responding during
self test
The balancer controller board was not able to
communicate with the camera controller board
during power on self test.
Possible causes:
• the Cameras controller board is missing or
damaged
• the flat cable connecting the keyboard, the
balancer controller board and the Cameras
controller board is unplugged, damaged or
missing.
Call technical support for the following corrective
actions:
• check the Cameras controller board
• check the connections
• re-install the Cameras controller board
software.
E900
Unknown machine model.
E901
The machine is not calibrated.
..
_
..........