5750149-UIM-D-1219
Johnson Controls Ducted Systems 15
FIGURE 19: Thermostat Chart - Single Stage Heat Pump with Two Stage Variable Speed Furnace
$
6LQJOH6WDJH+HDW3XPS±7ZR6WDJH9DULDEOH6SHHG)XUQDFH
<
)LUVW6WDJH
&RPSUHVVRU
RU2
5HYHUVLQJ9DOYH
*
)DQ
<
6HFRQG6WDJH
&RPSUHVVRU
5
±9ROW+RW
:
)LUVW6WDJH+HDW
&
±9ROW&RPPRQ
&
±9ROW&RPPRQ
5
±9ROW+RW
<<
)XOO6WDJH&RPSUHVVRU
*
)DQ
7:267$*(
9$5,$%/(
63(('
)851$&(
6,1*/(67$*(
+($73803
&
±9ROW&RPPRQ
5
±9ROW+RW
<
)LUVW6WDJH
&RPSUHVVRU
:
7+(50267$7
<
)LUVW6WDJH
&RPSUHVVRU
2
5HYHUVLQJ9DOYH
'(+80
'HKXPLGL¿FDWLRQ
:
6HFRQG6WDJH+HDW
:
6HFRQG6WDJH+HDW
::
)LUVW6WDJH+HDW
:287
$X[+HDW
9$&+XPLGLVWDW
2SWLRQDO
127(5RRPWKHUPRVWDW0867
FRQWUROIRVVLOIXHORSHUDWLRQ
FIGURE 20: Thermostat Chart - Two Stage Air Conditioner with Two Stage Variable Speed Furnace
$
7ZR6WDJH$LU&RQGLWLRQHU±7Z R6WDJH9DULDEOH6SHHG)XUQDFH
<
)LUVW6WDJH
&RPSUHVVRU
RU2
5HYHUVLQJ9DOYH
*
)DQ
<
6HFRQG6WDJH
&RPSUHVVRU
5
±9ROW+RW
:
)LUVW6WDJH+HDW
&
±9ROW&RPPRQ
&
±9ROW&RPPRQ
5
±9ROW+RW
*
)DQ
7:267$*(
9$5,$%/(
63(('
)851$&(
7:267$*(
$,5
&21',7,21(5
&
±9ROW&RPPRQ
5
±9ROW+RW
<
&RPSUHVVRU&RQWDFWRU
::
)LUVW6WDJH+HDW
7+(50267$7
<
)LUVW6WDJH
&RPSUHVVRU
'(+80
'HKXPLGL¿FDWLRQ
:
6HFRQG6WDJH+HDW
:
9$&+XPLGLVWDW
2SWLRQDO
<
6HFRQG6WDJH
&RPSUHVVRU
<<
)XOO6WDJH&RPSUHVVRU