Subject to change without notice. Published in U.S.A 5750149-UIM-D-1219
Copyright © 2019 by Johnson Controls. All rights reserved. Supersedes: 5750149-UIM-C-1019
York International Corp.
5005 York Drive
Norman, OK 73069
LP Conversion Kit Installed By
Supply static before indoor coil (in w.c.")
Return Static (in w.c.") before lter
Total External Static Pressure
Installation debris disposed of and furnace area cleaned up?
Red (Low) Yel (Med Low)
Blue (Med/Med High)
Blue (Med/Med High)
Black (High)
Air Side: System External Static Pressure
Owner Education
Calculated input in btuh - clock the gas meter in high re (Nat Gas Only)
Low Fire Manifold Gas Pressure (in. w.c.")Inlet Gas Pressure (in. w.c.")
Gas Side
Gas Type
Natural Gas LP Gas (Requires LP conversion kit)
LP Gas Conversion Kit Part # Used
Burner ame inspected -- ames are blue and extending directly into the primary heat exchanger cells
Air Side: Continuous Fan (PSC)
Clean Up
Supply static after indoor coil (in w.c.")
Return Static (in w.c.") after lter (furnace side)
Cycle Test
Give owner the owner's manual provided
Explain operation of system to equipment owner
Explain the importance of regular lter replacement and equipment maintenance
Explain thermostat use and programming (if applicable) to owner
Operate the furnace through several heating cycles from the thermostat, noting and correcting any problems
Operate the furnace through continuous fan cycles from the thermostat, noting and correcting any problems
Operate the furnace through cooling cycles (as applicable), noting and correcting any problems
Air Side: Heating (PSC)
Low Heat Blower Speed Selected
High Heat Blower Speed Selected
Red (Low) Yel (Med Low)
Black (High)
Blower Speed Selected
Lo Heat HI Heat Lo Cool
Hi Cool
High Fire Manifold Gas Pressure (in. w.c.")
D
Other Jumpers
De-humidistat
Air Side: Heating (Variable Speed ECM)
Heat Speed Selected
ABC
Temperature rise in degrees F measured in Low re
Temperature rise in degrees F measured in high re
Yes No
Heat Pump
Yes No
Red (Low) Yel (Med Low)
Blue (Med/Med High)
Blue (Med/Med High)
Black (High)
Air Side: Cooling (PSC)
Low Cool Blower Speed Selected
High Cool Blower Speed Selected
Red (Low) Yel (Med Low)
Black (High)
Air Side: Cooling (Variable Speed ECM)
A
B
C
D
A
B
C
D
COOL Speed Selected
ADJUST Setting
DELAY Setting
A
B
C
D
Air Side: Continuous Fan (Variable Speed ECM)
Lo Cool HI Cool Hi Heat taeH oLtaeH oL VSG
Blower (5-Speed) Selected
Blower (3-Speed) Selected
L (Low) M (Med) H (High)
Temperature rise in degrees F measured in low re
Temperature rise in degrees F measured in high re
Cooling CFM delivery (use Blower Performance Data Chart)
Hi Low

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls TM9V C Series and is the answer not in the manual?

Johnson Controls TM9V C Series Specifications

General IconGeneral
BrandJohnson Controls
ModelTM9V C Series
CategoryFurnace
LanguageEnglish

Related product manuals