7
138344_Rev_D - C450 Kennebec 8.2.10
Installation
Masonry Fireplace Requirements
The entire fireplace and chimney must be cleaned
and inspected before installation. The system
must meet local building code requirements.
The structure and components must be free of
any defects such as cracks or broken bricks or flue
tiles. Any damage must be repaired before instal-
lation.
Any opening that may exist between the masonry
of the fireplace and the facing masonry must be
permanently sealed.
The chimney must have a clay tile liner or a stain-
less steel liner utilizing a positive connection.
DO NOT REMOVE BRICKS OR MORTAR FROM
THE FIREPLACE OR CHIMNEY STRUCTURE. How-
ever, masonry or steel may be removed from the
smoke shelf and adjacent damper frame area
to accommodate installation of a chimney liner,
provided that their removal will not weaken the
structure of the fireplace or chimney, and will not
reduce protection for combustible materials.
CHIMNEY HEIGHT:
Minimum - 15 ft. ( 4.57 meters)
Maximum - 33 ft. (10.5 meters)
Factory-Built Fireplace Requirements
The Jøtul C450 may be installed into a factory-built
fireplace with the following conditions:
The factory-built fireplace must be listed per
UL 127 or ULC S610.
Installation must include a full height listed chim-
ney liner meeting type HT requirements (2100F)
per UL 1777 (U.S.) or ULC S635 (CAN). The liner
must be securely attached to the insert flue collar
and the chimney top.
The damper or fireplace front must be sealed to
prevent passage of room air into the the chimney
cavity.
Circulating air chambers (i.e. in a steel fireplace
liner or metal heat circulator) may not be blocked.
Air flow within and around the fireplace shall not
be altered by installation of the insert. The C 450
Surround Panels comply with this requirement.
Alteration of the fireplace is limited to
a) removal of the damper for liner installation
b) removal of external, non-functional trim which
must be stored within the fireplace for replace-
ment.
• Fireplace Conversion Notice PN 220508 must be
permanently attached to the back of the fireplace.
This metal label is included in the bag containing
this manual.
Final approval is contingent on the authority hav-
ing local jurisdiction.
Minimum Fireplace Dimensions
A: FRONT WIDTH * ..........................27 1/2” (698 mm)
B: HEIGHT .............................................. 23” (584 mm)
C: REAR WIDTH .............................. 25 1/2” (648 mm)
D: REAR HEIGHT ............................. 21 1/2” (546 mm)
E: DEPTH .................................................14” (355 mm)
Figure 5. Minimum Fireplace Dimensions
*NOTE: Width dimension accommodates clearance for
Surround attachment to the front of the firebox.