1.0 Relationship to the
authorities
• Installationofareplacemustbecarriedoutincompliance
with national laws and regulations. All local ordinances,
including those that refer to national and European
standards, must be complied with when products are
installed.
• The installation can only be put into use after it has been
checkedbyaqualiedinspector.
• Contact your local building authorities before installing a
newreplace.
2.0 Technical data
Material: Cast iron
Finish: Paint
Smokeoutlet: Top
Fluepipedimension: Ø150mm
Outsideairconnection: Ø80/Ø100mm
Productweight: 170kg
Optional extras Cover for outside air through
base
Productdimensions,distances:SeeFig. 1
Technical data in acc. with EN 13240
Nominalheatoutput: 7,0kW
Fluegasvolume: 7,1g/s
Chimneydraught,EN13240: 12Pa
Recommendednegativepressure
insmokeoutlet: 16-18Pa
Efciency: 77%
COemissions(13%O
2
): 0,07%
COemissions(13%O
2
): 884mg/Nm
3
NOxat13%O
2
: 54mg/Nm
3
OGC@13%O
2
: 60mg/Nm
3
ParticleemissionNS3059: 1,88g/kg
Airconsumption: 6,0litre/secor21,6m
3
/h
Chimneytemperature,EN13240: 305
o
C
Dust: 14mg/Nm
3
@13%O
2
Typeoffuel: Wood
Max.loglength: 30-50cm
Fuelconsumption: 2,3kg/h
Max.kindlingamount: 3,4kg
Nominalkindlingamount: 1,7kgin2-3pieces
Operation: Intermittent
Intermittentcombustionheremeansnormaluseofareplace,
i.e. add more fuel as soon as the re has burned down to
embers.
ENGLISH
Table of contents
1.0 Technicaldata ......................................... 6
2.0 Relationship to the authorities .................. 6
3.0 Safety ....................................................... 7
4.0 Installation ............................................. 11
5.0 Daily Use ................................................ 14
6.0 Maintenance ........................................... 16
7.0 Servicing ................................................ 16
8.0 OptionalExtras ....................................... 18
9.0 Recycling ................................................ 18
10.0Warranty ................................................ 19
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number
when contacting your retailer or
Jøtul.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Serial no.