TRANSDUCERINSPECTION
INSURATION
1 TRANSDUCER
MeasurementtheTransducerinsulationresistance.(includetransducercable)
1 TransducercableisremovefromtheterminalofMatchin
Box.
2 Measurethefollowin
corecablesbytheinsulationresistancemeter(DC500V).
3 Whiteandblack,whiteandscreen,blackandscreen.
Eachcorecableand
'sbody).
4 Ifresistanceisbeyond10MΩ,Transducerisnormalasaresultofthemeasurement.
Incaseoffollowin
lacethetransducerindrydock.
5 Ifresistanceislessthan10MΩ,Transduceris
oorasaresultofthemeasurement
Measurement 1.TRANSDUCER 2.EXTEN.CABLE
White−Black
White−Screen
Black−Screen
White−Ground
Black−Ground
Screen−Ground
StandardOver10MΩ
2 EXTENTIONCABLE
MeasurementtheExtensionCableinsulationresistance.
1 Removethefollowin
alltransducercables.
TerminalofEchosounder,Matchin
(Junction)Box,
RemovecableRemovecabl
JFE-582(585) JunctionBox Transducer
2 Measurethefollowin
corecablesbytheinsulationresistancemeter(DC500V).
3 Whiteandblack,whiteandscreen,blackandscreen.
Eachcorecableand
'sbody).
4 Ifresistanceisbeyond10MΩ,ExtensionCableisnormalasaresultofthemeasurement
Incaseoffollowin
lacetheextentioncableindrydock.
5 Ifresistanceislessthan10MΩ,ExtensionCableis
oorasaresultofthemeasurement