ġ
4-26
4
[II] Reception Monitor Adjustment (MON Indicator Adjustment)
Adjust the circuit for monitoring the reception performance of the radar equipment.
Procedures 1. Open Adjust Menu.
4. TXRX Setting
4. MON
3. MON Indicator Adjustment
2. Increase or decrease the adjustment
value so that the performance monitor
level indicator will be adjusted to "8."
3. Press the [EXIT] button to close the adjustment menu.
Note:
During performance monitor adjustment, all acquisitions by the target tracking function are released.
The released target acquisitions are not recovered.