5-48 
5.5  Alarm Display 
yy
yyy
5
 
Gyro Set Alarm 
 
The GYRO I/F in this system receives signals from a gyro. Even if the power is turned off, the system will 
follow up the gyro. However, the system stops the follow-up operation when the power of the master gyro is 
turned off or when any trouble occurs to the line. When the power of the master gyro is recovered, the   
  Set Gyro    alarm will be generated. 
If this alarm occurs, set the gyro. 
 
Gyro Set Alarm 
 
Alarm characters
  Alarm sound 
Conditions 
Set Gyro  Beep sound (pipi-pipi)
The signals from the gyro are stopped, but the gyro is 
recovered.