– 24 –
Adjustmentprocedure
1. Select No. 2: FAGOTT of the service mode.
2.Graduallyturnadjustingshaft
❷
tondapositionwheretheneedledeviatesslightly.Now,temporarily
tighten screw
❶
.
3. Slightly loosen setscrew
❸
.Adjustthelateralbalanceoftheneedlebarbyslightlymovingright-leftadjust-
er
❹
while carefully listening to the noise produced when the needle deviates at the right and left needle
entry points. Then, securely tighten setscrew
❸
.
4. Additionally turn shaft
❷
and securely tighten screw
❶
at the position where the needle does not deviate.
5.LightlytapPsectionwithngers.Ifyouhearaneedledeviationnoiseattherightandleftneedleentry
points,theoptimumclearanceisprovidedbetweentheneedleandthehook.
6. Lightly pressing shaft
❻
in the direction of the arrow, securely tighten screw
❺
.
P section
❹
❸
❶❶
❺❺
❷❷
❻❻