EasyManua.ls Logo

JUKI HZL-UX8 Series - Needle to Hook Blade Clearance

JUKI HZL-UX8 Series
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 23 –
6-9 Clearance between the needle and the blade point of hook
Remove the face cover and the throat plate.
Adjustmentprocedure
1. Loosen screw
and
.Adjusttheclearancebetweentheneedleandthebladepointofthehookto0.02
to0.07mmbyturningadjustingshaft
.
Left needle position Right needle position Right needle positionLeft needle position
If the clearance is larger at the right needle
entry point, shift
to the right.
If the clearance is larger at the left needle
entry point, shift
to the left.
Adjustingthebalanceoftheclearancesattherightandleftneedleentrypoints
1.Selectthezigzagpatternandsetthezigzagwidthto7mm.Adjustthebalanceoftheclearancesprovided
betweentheneedleandthebladepointofthehookattherightandleftneedleentrypoints.
0.02 to 0.07 mm