38
6-4. How to use the temporary stop
Once the RESET key function is set to the "pause" by means of the memory switch U031, the RESET key
will function as the pause key to allow the sewing machine to be stopped during sewing. (Refer to
"I.8-2. List
of the memory switch functions" p.57
.)
1) The sewing machine is stopped by pressing
RESET key
󱀁
. At this time E050 is
displayed. The error is reset by pressing RESET
key
󱀁
. Then, the feed forward/backward
screen is displayed.
2) Three operations can be carried out after the
error is reset.
1. Re-starting of sewing with the start switch
2. Thread trimming by pressing RESET key
󱀁
, position adjustment with DATA CHANGE key
󱀅
, then re-starting of sewing with the
start switch.
3.
Thread trimming by pressing RESET key
󱀁
.
Then, origin retrieval by re-pressing RESET
key
󱀁
.
󱀅
󱀁
󱀁