−11
Standard Adjustment
(7) Position of the loop guide
0 to 0.05mm
0 to 0.05mm
MP-200NL
MP-200NS
3
4
5
8
9
3
4
8
9
Slight contact
Standard Adjustment
(8) Adjusting the needle and the looper
NS : 2mm
NL : 3mm
MP-200NS MP-200NL
1
2
3
4
5
6
7
A
1
2
B
3
4
3
4
5
0 to 0.05 mm
5
(Caution) Figures above are those as observed
from the underside of machine bed.