−7
Standard Adjustment
(4) Feed cam timing
d
Bottom end of metal is aligned
with 4th engraved marker line.
1
2 (Screw No. 2)
3
4
5
6 (Screw No. 1)
Standard : 2 and 6 are almost aligned
with each other.
Top surface of feed dog is
aligned with top surface of
throat plate.