5. OPERATION
COMPRESSOR MENU (compressor button) 5.5
Compressor menu shows compressor settings.
Adjustments are made by pushing and turning SELECT knob (see 5.1).
CMP RATIO RANGE PRO
ON 1.8 6 5
CMP: compressor on/off
(by pushing SELECT knob, green LED in button
lits if function block is switched on)
RATIO: compressor ratio 1.0:1 ...4.0:1 in 13 steps
RANGE: compression range (maximum compression
gain) 0 ... +15 dB
PRO: adjustment of processing characteristic
(range of time constant values for adaptive
processing) for optimum processing results
from 0 (very fast) to 9 (very slow)
> see application notes!
LIMITER MENU (limiter button) 5.6
Limiter menu shows limiter settings.
Adjustments are made by pushing and turning SELECT knob (see 5.1).
LIM THRS PRO
ON -9.0 1
LIM: limiter on/off
(by pushing SELECT knob, green LED in button
lits if function block is switched on)
THRS: limiter threshold level -20 ... 0 dBFS
PRO: adjustment of processing characteristic
(range of time constant values for adaptive
processing) for optimum processing results
from 0 (very fast) to 9 (very slow)
> see application notes!
EXPANDER MENU (expander button) 5.7
Expander menu shows expander settings.
Adjustments are made by pushing and turning SELECT knob (see 5.1).
EXP THRSH RANGE REL
ON -32 31 2.0
EXP: expander on/off
(by pushing SELECT knob, green LED in button
lits if function block is switched on)
THRSH: expander threshold -60...-20dBFS
RANGE: expander range 0...+40 dB, GATE
REL: expander release time 0.2 ... 4 sec
Operation manual accent2, chapter 5 -Operation- page 5-3