EasyManuals Logo

Jungheinrich EJD 220 User Manual

Jungheinrich EJD 220
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #225 background imageLoading...
Page #225 background image
29
02.16 EN
9 Storing the battery
NOTE
The battery should not be stored for longer than 3 months without charging as
otherwise it will no longer be functional.
If the battery is to be taken out of service for a long period, it should be stored fully
charged in a dry room protected from frost. To ensure the availability of the battery
the following charges can be selected:
Monthly compensation charge for PzS and PzB batteries or 4-monthly full charge
for PzV batteries.
Trickle charge for a charging voltage of 2.23 V x number of cells for PzS, PzM and
PzB batteries or 2.25 V x number of cells for PzV batteries.
If the battery is to be taken out of service for a long period ( > 3 months), it should, as
far as possible, be charged to 50% of its charge level and stored in a dry room
protected from frost.
10 Troubleshooting
If any faults are found on the battery or charger, contact the manufacturer's customer
service department immediately.
Z The operations required must be carried out by the manufacturer's customer
service department or a customer service organisation authorised by the
manufacturer.
11 Disposal
Batteries marked with the recycling symbol and the sign showing a
crossed-out rubbish bin should not be disposed of with ordinary
household waste.
Buy-back terms and type of recycling are to be agreed with the
manufacturer as described in § 8 of the battery legislation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jungheinrich EJD 220 and is the answer not in the manual?

Jungheinrich EJD 220 Specifications

General IconGeneral
BrandJungheinrich
ModelEJD 220
CategoryForklifts
LanguageEnglish

Related product manuals