disable;
}
interface ge-0/1/0.0;
interface ge-5/2/7.0;
}
}
}
CFM on L2-CE1 Here is the configuration of CFM on L2-E1:
[edit interfaces]
ge-5/2/3 {
vlan-tagging;
unit 0 {
vlan-id 2000;
}
}
[edit protocols oam]
ethernet {
connectivity-fault-management {
maintenance-domain customer {
level 7;
maintenance-association customer-site1 {
continuity-check {
interval 1s;
}
mep 800 {
interface ge-5/2/3.0;
direction down;
auto-discovery;
}
}
}
}
}
CFM on L2-CE2 Here is the configuration of CFM L2-CE2:
[edit interfaces]
ge-0/2/9 {
vlan-tagging;
unit 0 {
vlan-id 2000;
}
}
[edit protocols oam]
ethernet {
connectivity-fault-management {
maintenance-domain customer {
level 7;
maintenance-association customer-site1 {
continuity-check {
interval 1s;