EasyManua.ls Logo

JVL MAC050 - Page 189

JVL MAC050
478 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500 185
5.6 Expansion Mod. MAC00-FC2/FC4/FC41
5.6.11 Baud-rate:
The Baud-rate can be set according to the following table, and is selected on the Dip
switch SW1 dip 8-10, as shown on the figure below:
The factory default settings sets the module to have a Baud-rate of 500 kbit.
The Baud-rate is the external communication speed. Please notice that internal execu-
tion time can be the main limitation meaning that data will be received at the selected
Baud-rate but not necessarily executed at the same time.
The Baud-rate setting can only be done in the hardware, it is not possible to set this by
using the MacTalk software.
Baud-rate Dip Switch no. (SW1)
10 9 8
1000 kbit OFF OFF OFF
500 kbit (factory default) OFF OFF ON
250 kbit OFF ON OFF
125 kbit OFF ON ON
100 kbit ON OFF OFF
50 kbit ON OFF ON
20 kbit ON ON OFF
10 kbit ON ON ON
1
2
4
5
7
8
9
0
6
3
MAC00-FC2 and FC4 Dip switch settings
Dip 1-7 - Node-id setting
(address range 0-127)
TT1070GB
Mini dip-switch
SW1
Dip 8-10 - Baud rate
(Baud rate setting 10k to 1000k)
OFF ON
Rear side of the MAC00-FC2 or FC4
expansion module
SW1 Default: Switch1-8 “ON”
and Switch 9+10 “OFF”