JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500 283
5.8 Expansion Module MAC00-FP2/FP4
5.8.14 Expansion MAC00-FP4 hardware description
The MAC00-FP4 offers IP67 on MAC050-141 protection and M12 connectors which
make it ideal for automation applications where no additional protection is desired. The
M12 connectors offer solid mechanical protection and are easy to unplug compared to
the FP2 module which has cable glands. The signals available are restricted compared to
the FP2 module since only 4 I/O terminals are available. The I/O’s connected to these 4
terminals must be selected by a small dip-switch.
The connector layout:
(Continued next page)
“PWR” - Power input. M12 - 5-pin male connector
Signal
name Description
Pin
no.
JVL Cable
WI1000M1
2
F5T05N
Isolation
group
P+
Main supply: MAC050-141=+8-48VDC.
MAC400 to 4500=+18-32VDC.
Connect with pin 2 *
1 Brown 1
P+
Main supply: MAC050-141=+8-48VDC.
MAC400 to 4500=+18-32VDC.
Connect with pin 1 *
2 White 1
P- Main supply ground. Connect with pin 5 * 3 Blue 1
CV
Control voltage: MAC050-141=+8-48VDC.
MAC400 to 4500=+18-32VDC.
4 Black 1
P- Main supply ground. Connect with pin 3 * 5 Grey 1
* Note: P+ and P- are each available at 2 terminals. Make sure that both terminals are connected in order to split the supply
current in 2 terminals and thereby avoid an overload of the connector.
“BUS1” - Profibus-DP interface. M12 - 5-pin male connector
Signal
name Description
Pin
no.
Cable:
user
supplied
Isolation
group
- Reserved for future purpose - do not connect 1 - 2
A-
Terminal A (Siemens syntax) for the Profibus-DP
interface
2 - 2
DGND Profibus-DP interface ground 3 - 2
B+
Terminal A (Siemens syntax) for the Profibus-DP
interface
4 - 2
SHIELD Cable shield. Internally conn. to the motor housing. 5 - 2
BUS1
Primary Profibus-DP
connector.
M12 - 5pin male
connector including:
Profibus-DP interface
Expansion module MAC00-FP4 front plate
PWR
Power
M12 - 5pin male
connector including:
P+, P- and secondary
supply (optional).
I/O
M12 - 8pin female
connector including:
RS232 Interface
Selectable I/O’s such
as analogue input, O1,
O2, IN1, NL, PL.
BUS2
Secondary Profibus-DP
connector:
M12 - 5pin female
connector including:
Profibus-DP interface
TT1008GB