JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500 291
5.9 Expansion Module MAC00-FS1/FS4
5.9.3 Expansion MAC00-FS4 hardware description
The MAC00-FS4 offers a IP67 on MAC050-141 protection and M12 connectors which
makes it ideal for automation applications where no additional protection is desired. The
M12 connectors offers a solid mechanical protection and are easy to operate.
The connector layout:
(Continued next page)
“PWR” - Power input. M12 - 5pin male connector
Signal
name Description
Pin
no.
JVL Cable
WI1000-
M12F5T05
N
Isolation
group
P+
Main supply: MAC050-141=+8-48VDC.
MAC400 to 4500=+18-32VDC.
Connect with pin 2*
1 Brown 1
P+
Main supply: MAC050-141=+8-48VDC.
MAC400 to 4500=+18-32VDC.
Connect with pin 1*
2 White 1
P- Main supply ground. Connect with pin 5 * 3 Blue 1
CV
Main supply: MAC050-141=+8-48VDC.
MAC400 to 4500=+18-32VDC.
Connect with pin 2*
4 Black 1
P- Main supply ground. Connect with pin 3 * 5 Grey 1
* Note: P+ and P- is each available at 2 terminals. Make sure that both terminals are connected in order to
split the supply current in 2 terminals and thereby avoid an overload of the connector.
“COM” - Interface RS485. M12 - 5pin female connector
Signal
name Description
Pin
no.
JVL Cable
WI1000M1
2
M5T05N
Isolation
group
- Leave open 1 Brown 1
- Leave open 2 White 1
RS485 A-
RS485 interface positive terminal.
Leave open if unused
3 Blue 2
RS485 B+
RS485 interface negative terminal.
Leave open if unused
4 Black 2
GND Interface ground 5 Grey 2
IO1
Basic I/O’s
M12 - 8pin male
connector including:
Digital inputs 1 to 4, and
O1, O2, IO supply.
Expansion module MAC00-FS4 front plate
IO2
Extended I/O’s
M12 - 8pin female
connector including:
232 interface and GND
Multifunction I/O’s (A+...),
analogue input AIN, and
RS
TT1058GB
PWR
Power supply
M12 - 5pin male
connector including:
and
P+ (primary supply), and CV
(secondary supply) P-
COM
RS485 Communication
M12 - 5pin female
connector including:
RS485 Interface.