Compressed air system
ABT 37 ABT 57
Pressure drop [psi]
(in relation to 100 psig
working pressure)
3 3
Maximum permitted work‐
ing pressure [psig]
230 230
Tab. 28 Refrigeration dryer: compressed air system
Refrigerant circuit
ABT 37 ABT 57
Refrigerant R134a R134a
Global warming potential
(GWP)
1300 1300
Charge quantity* [lb]
Maximum permitted work‐
ing pressure [psig]
305 305
Safety pressure switch:
shutdown pressure [psig]
305 305
* Read off the charge quantity from the dryer nameplate and enter it in the table.
Tab. 29 Refrigeration dryer: refrigeration circuit
2 Technical Data
2.16 Refrigeration dryer
9_5721 06 USE
Service Manual Screw Compressor
ASD T Tri-Voltage
13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASD 25 and is the answer not in the manual?

KAESER ASD 25 Specifications

General IconGeneral
ModelASD 25
TypeScrew Compressor
Free Air Delivery2.5 m³/min
Motor Power15 kW
Sound Level68 dB(A)
Dimensions (L x W x H)1250 x 810 x 1170 mm (49.2 x 31.9 x 46.1 in)
Pressure8 bar