Your KANE988 prints test results using an optional infrared printer or
wirelessly sends test results to the KANE LIVE App.
MEMORY
Your KANE988 stores:
Combustion logs = 178
Pressure/Temp logs = 178
Airflow logs = 89
DTHA2 logs = 89
Tightness logs = 146
Average logs = 117
Timed Logs = 2 * 1440
You can enter 2 lines of 24 characters to personalise your test results.
KANE LINK
You can wirelessly connect optional KANE LINK devices to your analyser.
When connected, they stay connected until you use KANE LINK to remove
them.
When powered on, KANE LINK devices replace or add measurements to
your analyser.
See page 37 to add or remove optional KANE LINK devices.
CO PROTECTION AND AUTO RANGE
Your KANE988 has an electrochemical CO sensor measuring to 10,000ppm
and an NDIR CO sensor measuring to 100,000ppm / 10%.
Above 10,000ppm the NDIR sensor automatically manages CO to
100,000ppm / 10% while the electrochemical CO sensor is protected by the
over range protection pump.
KANE988 MANUAL 5