LF.33 provides an offset to the gain value at low speeds. Again this parameter provides two
adjustments; one for acceleration and one for deceleration. During starting and stopping
it is necessary to have higher gain values to overcome friction as well as maintain good
control. The total integral gain value is the sum of LF.32 and LF.33 at low speeds.
US.20 and US.21 de ne the corner speeds where the gain begins to ramp up and where
the gain reaches the maximum value. For gearless application it may be necessary to
increase US.21 to around 100 ft/min and decrease US.20 to 3 ft/min
Common problems during starting and their solutions
Initial Start Up
Speed
t
LF.33 = 1000
Speed lags the command on take off. This is typical with
worm gear machines when trying to break free. The
start feels very hard or abrupt. Raise in steps of 500.
Speed
t
LF.33 = 3000
Higher KI Offset value aids the torque build during
starting. Helps to over come break away torque of
machine. Actual speed tracks the command.
Speed
t
LF.33 = 6000
High KI Offset value causing vibration or audible noise
in the motor at take off. Lower in steps of 500.

Table of Contents

Other manuals for KEB ACOMBIVERT F5 X3A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB ACOMBIVERT F5 X3A and is the answer not in the manual?

KEB ACOMBIVERT F5 X3A Specifications

General IconGeneral
BrandKEB
ModelACOMBIVERT F5 X3A
CategoryDC Drives
LanguageEnglish

Related product manuals