P30 x-series System overview
Configuration manual V4.01
13
© KEBA
Information
The Ethernet2 connection X3 (RJ45) is for diagnose purposes (debugging)
only and may not be used to connect to a network.
The Ethernet1 connection X4 (LSA+
®
) and the Ethernet2 connection X3
(RJ45) are connected in parallel on the PCB and can not be used at the
same time! The connection that is not used must be unplugged.
3.1.2 WLAN
The P30 x-series charging station can be connected to a router via the inte-
grated WLAN interface. If the router is connected to the Internet, a connec-
tion to an OCPP backend can be made.
The technical data of the WLAN module can be found in the "Installation
Manual".
Information
Only a charging station that ist operated as a single charging station can be
connected to the router via WLAN. A charging station that is part of a
charging network (master/slave network) must always be connected to the
router via LAN. Otherwise, there may be data transmission errors (e.g.
faulty software update) between the master charging station and the slave
charging stations.