4 Configuration
This chapter describes the necessary configuration for the correct operation
of the charging stations. The following steps are necessary for this:
Set the DIP switch on the charging station
Configuration (via the web interface or via USB stick)
Depending on the network configuration, activation of the DHCP server on
the master charging station may be necessary.
4.1 Connection panel
In the connection panel of the charging station are important interfaces and
controls for the configuration of the charging station. To access, the housing
cover and the connection panel cover must be removed.
Illustration4-6: Connection panel
DSW1 ... DIP switch DSW2 ... DIP switch
Service ... Service button LED ... Status LED
X1 ... Enable input X2 ... Switch contact output
X3 ... Ethernet2 connection (RJ45) X4 ... Ethernet1 connection (LSA+®)
SIM ... Slot for SIM card (GSM module is
optional)
USB ... USB interface
Shd ... Ground for Ethernet1 connection