P30 x-series Configuration
Configuration manual V4.01
21
© KEBA
4.2 DIP switch settings
This DIP switch setting must be made for each master and slave charging
station to enable charging station communication.
Caution
Possible damage to the DIP switches!
The DIP switches are rocker switches and not slider switches. The DIP
switches must be pressed and must never be slid.
ON/OFF position of the rocker switches
The illustration shows the position of the rocker switches for the setting ON
and OFF
The DIP switches are located under the connection panel cover. The follow-
ing figure shows only the affected DIP switches, others are not shown. The
following setting must be made on the DIP switch DSW2:
Activation of communication - DSW2.5
Function Figure
Activation of communication
Information
Changes to the DIP switch settings only become effective after a restart of
the charging station!
To restart, press the "Service button" until the first signal tone sounds (ap-
prox. 1 second) or switch off the charging station for a short time via the
line circuit breaker.

Other manuals for Keba KeContact P30 x-series