O
ohms 3-9
Open interlock indication
3-14
OPER
3-13
Operation keys
1-9, 1-14
Optional command words
1-27
Options and accessories
1-4
Overview of this manual
1-2
P
Package content 1-4
Parameter
7-7
Performance considerations
3-2
Phone number
1-3
Piezoelectric and stored charge effects
B-3
POWER
1-9, 1-13
Power module
1-12, 1-17
Power-up
1-19
Power-up sequence
1-20
Precautions
3-5
Programming
C-2
Q
Query commands 1-27
R
Rack mount kits 1-7
Range
4-2
keys
1-10, 1-14
Units, Digits, Rate, and Filters
4-1
Rate
1-10, 1-14, 4-4
Rear panel
1-11, 1-16
Rear panel summary
1-11, 1-16
RECALL
1-10, 1-14
Recall
6-2
REL
1-9, 1-10, 1-13, 1-15
Relative
5-1
Relative, mX+b, m/X+b (Reciprocal), and
Log
5-1
REM
1-10, 1-15
Remote
7-1
REN (remote enable)
7-6
resistivity
2-11
Response
time
4-6
Restoring
1-21
RS-232
1-12, 1-17
connections
7-2
RS-232
7-2
RS-232 interface
7-2
S
Safety interlock 2-13
safety shield
3-6, 3-10
Safety symbols and terms
1-3
SAVE
1-10, 1-14
Saving
1-21
scientific (SCI)
4-3
scientific notation
1-12, 1-18
SCPI
3-11, 3-14, 4-6, 6-5, 7-6
SCPI commands
amps function
3-8, 3-11
buffer
6-4
SCPI programming
mX+b, m/X+b, and log
5-4
range and digits
4-3
relative
5-2
zero check and zero correct
3-4
select power-on setup
1-21
serial number
1-26, 1-27
Setting and controlling relative
5-2
SETUP
1-10, 1-14
Shielding
2-9
Signal
7-5
SLOW
1-10, 1-15
Sourcing
3-1, 3-13
Special keys and power switch
1-9, 1-13
Specifications
A-1
SRQ
1-10, 1-15
STAT
1-10, 1-15
statistics
6-3
Status
1-12, 1-18
STD DEV
6-3
STORE
1-10, 1-14
Store
6-2
Sweeps
6-1
sweeps
6-5
T
TALK 1-10, 1-15
Test fixture
2-9
TIMER
1-10, 1-15
timestamps
6-3
Triboelectric effects
B-3
TRIG
1-9, 1-10, 1-14, 1-15
TRIGGER LINK
1-12, 1-17
U
Units 4-3
Unpacking and Inspection
1-3
user setup
1-21

Table of Contents

Other manuals for Keithley 6487

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 6487 and is the answer not in the manual?

Keithley 6487 Specifications

General IconGeneral
TypePicoammeter/Voltage Source
Current Measurement Range20 fA to 20 mA
InterfacesGPIB, RS-232
Voltage Burden< 200 µV
Input Impedance>10^14 Ω
Power100 V / 120 V / 220 V / 240 V
Basic Current Measurement Accuracy0.4%