4.3 ELECTRIC NETWORK OVERVOLTAGE OR UNDERVOLTAGE
Ifthepowersourceisusedinanelectricnetworkwithinsucientvoltage(lessthan300V),
the control features of the device are disabled automatically.
Theprimarycircuitsofthepowersourceareprotectedagainstpowerspikes.Theproduct’s
mains voltage range is broad enough to prevent overvoltage problems at up to 440 V (see
Section8,Technicalspecications’).Makesurethatthevoltageremainswithintheallowed
range, especially if the operating power is supplied by a generator set.
4.4 MISSING PHASE IN THE ELECTRIC NETWORK
If a phase is missing from the mains current, the welding features will be adversely aected or
themachinemayhaveproblemsstarting.Lossofaphasecanbecausedbya:
• Blownmainsfuse.
• Damagedmainscable.
• Poormainscableconnectioninthemachine’sterminalblockormainssocket.
4.5 MACHINE ERROR CODES
The machine always checks its operation automatically during start-up and reports any
failures detected. If failures are detected during start-up, they are shown as error codes on the
control panel display.
Power source error codes
Err3 Power source overvoltage
The machine has stopped the welding because it has detected momentary voltage spikes or
continuous overvoltage dangerous to the machine in the electric network. Check the quality
of the supply network.
Err4 Power source overheating
Thepowersourcehasoverheated.Thecausemaybeoneofthefollowing:
1) Thepowersourcehasbeenusedforalongtimeatmaximumpower.
2) The circulation of cooling air to the power source is blocked.
3) Thecoolingsystemhasexperiencedafailure.
Remove any obstacle to air circulation, and wait until the power source fan has cooled down
the machine.
Err5 Water unit alarm
Thewatercirculationisblocked.Thecausemaybeoneofthefollowing:
1) Congestion or disconnection in the cooling pipeline.
2) Insucientcoolingliquid.
3) Excessivecoolingliquidtemperature.
Check the circulation of the cooling liquid and the air circulation of the water unit.
Err23 Power source overvoltage warning
The power source has detected voltage spikes in the electric network. Short power spikes
can be managed. They do not lead to interruptions in welding but may decrease the welding
quality. Check the quality of the supply network.
Err61 The water unit is not found
The water unit is not connected to the equipment, or the connection has failed.
Set the machine to gas cooling (3.3.7) if you are using a gas-cooled welding gun, or connect a
water unit.
Err154 Overloading of the wire feed motor
The welding has been interrupted because the wire feeding engine power has risen to a high
level. The cause may be congestion in the wire line. Check the wire lead, contact tip, and feed
rollers.
Err155 Warning of the wire feed unit overheating
The voltage level of the wire feeding engine has increased. The cause may be a stained wire
lead or a gun cable that is twisted at a sharp angle. Check the state of the gun, and clean the
wire line if this is necessary.
EN
13
FastMig KM 300, 400, 500 / © Kemppi Oy /0901
FI
SV
NO
DA
EN
DE
NL
FR
ES
PL
RU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi FastMig KM400 and is the answer not in the manual?

Kemppi FastMig KM400 Specifications

General IconGeneral
BrandKemppi
ModelFastMig KM400
CategoryWelding System
LanguageEnglish

Related product manuals