FastMig Pulse 350, 450
14
EN
DOUBLE PULSE MIG
WFSpeed
0.7 – 25 m/min * 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
-9.0 ... +9.0 Factory setting is 0.0
( = curve point)
0.5 steps
Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.
FineTuningMax
-9.0 ... +9.0 0.5 steps Set the limit for maximum arc length
FineTuningMin
-9.0 ... +9.0 0.5 steps Set the limit for minimum arc length
Dynamics
-9 ... +9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Current
-10% ... +15% Factory setting
is 0%
Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%
DPulseAmp
0.1 – 3.0 m/min Factory setting is
CURVE
Adjusts the amplitude of the WFSpeed in 0.1 m/min
steps. Value comes from Welding program.
DPulseFreq
0.4 – 8.0 Hz Factory setting is
CURVE
Adjusts the frequency of the double pulse in 0.1 Hz
steps. Value comes from Welding program.
WISEROOT / WISETHIN
WFSpeed
0.7 – 14 m/min * 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
BaseCurrent
-50 ... +50 Adjusts the base current of the curve – the arc length –
within certain limits.
BaseCurrentMax
-50 ... +50 1% steps Set the limit for maximum “arc length”
BaseCurrentMin
-50 ... +50 1% steps Set the limit for minimum “arc length”
FormingPulse
-30 ... +30 Adjusts the forming pulse current of the curve in certain
limits. In other words, it controls arc pressure.
FormingPulseMax
-30 ... +30 1% steps Set the limit for maximum forming pulse current
FormingPulseMin
-30 ... +30 1% steps Set the limit for minimum forming pulse current
StartTime
-9 ... +9 Factory setting is 0 Set how long arc behaves like normal synergic MIG/
MAG prosess after the arc start. It gives heat for the arc
start.
StartVoltage
-30 ... +30 Factory setting is 0 Set the arc voltage which is used during StartTime.
In other words, it adjusts the length of the arc during
StartTime.
* Dierent welding programs may further restrict the value range further.
MMA PROCESSES
Current
14 – 350A/450A Welding current
CurrentMax
14 – 350A/450A Set the limit for maximum current value
CurrentMin
14 – 350A/450A Set the limit for minimum current value
ArcForce
-9 ... +9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
StartPower
-9 ... +9 Factory setting is 0 Adjusts arc ignition

Other manuals for Kemppi FastMig Pulse 350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi FastMig Pulse 350 and is the answer not in the manual?

Kemppi FastMig Pulse 350 Specifications

General IconGeneral
BrandKemppi
ModelFastMig Pulse 350
CategoryWelding System
LanguageEnglish

Related product manuals