13
© Kemppi Oy / 1515
EN
4.3 Welding parameters and functions
4.3.1 Welding parameters
MIG
WFSpeed
0.7 – 25 m/min 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
Voltage
8.0 – 50.0V 0.1V steps Controls the length of the arc
VoltageMax
Set the limit for maximum voltage value
VoltageMin
Set the limit for minimum voltage value
Dynamics
-9 ... +9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
1-MIG
WFSpeed
0.7 – 25 m/min * 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
-9.0 ... +9.0 Factory setting is 0.0
( = curve point)
0.5 steps
Adjusts the arc voltage of the curve within certain
limits. In other words, it adjusts the length of the arc
within certain limits
FineTuningMax
-9.0 ... +9.0 0.5 steps Set the limit for maximum arc length
FineTuningMin
-9.0 ... +9.0 0.5 steps Set the limit for minimum arc length
Dynamics
-9 ... +9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
PULSE MIG
WFSpeed
0.7 – 25 m/min * 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
-9.0 ... +9.0 Factory setting is 0.0
( = curve point)
0.5 steps
Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.
FineTuningMax
-9.0 ... +9.0 0.5 steps Set the limit for maximum arc length
FineTuningMin
-9.0 ... +9.0 0.5 steps Set the limit for minimum arc length
Dynamics
-9 ... +9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Current
-10% ... +15% Factory Setting
is 0%
Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%.