EasyManuals Logo

Kemppi FastMig Pulse 350 User Manual

Kemppi FastMig Pulse 350
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
13
© Kemppi Oy / 1515
EN
4.3 Welding parameters and functions
4.3.1 Welding parameters
MIG
WFSpeed
0.7 – 25 m/min 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
Voltage
8.0 – 50.0V 0.1V steps Controls the length of the arc
VoltageMax
Set the limit for maximum voltage value
VoltageMin
Set the limit for minimum voltage value
Dynamics
-9 ... +9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
1-MIG
WFSpeed
0.7 – 25 m/min * 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
-9.0 ... +9.0 Factory setting is 0.0
( = curve point)
0.5 steps
Adjusts the arc voltage of the curve within certain
limits. In other words, it adjusts the length of the arc
within certain limits
FineTuningMax
-9.0 ... +9.0 0.5 steps Set the limit for maximum arc length
FineTuningMin
-9.0 ... +9.0 0.5 steps Set the limit for minimum arc length
Dynamics
-9 ... +9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
PULSE MIG
WFSpeed
0.7 – 25 m/min * 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
FineTuning
-9.0 ... +9.0 Factory setting is 0.0
( = curve point)
0.5 steps
Adjusts the base current of the curve in certain limits.
In other words, it adjusts the length of the arc in certain
limits.
FineTuningMax
-9.0 ... +9.0 0.5 steps Set the limit for maximum arc length
FineTuningMin
-9.0 ... +9.0 0.5 steps Set the limit for minimum arc length
Dynamics
-9 ... +9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lower
the value the softer the arc is. The higher the value the
rougher the arc is.
Pulse Current
-10% ... +15% Factory Setting
is 0%
Reduces the pulse current of the curve at the maximum
10% and raises it at the maximum 15%.

Other manuals for Kemppi FastMig Pulse 350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi FastMig Pulse 350 and is the answer not in the manual?

Kemppi FastMig Pulse 350 Specifications

General IconGeneral
BrandKemppi
ModelFastMig Pulse 350
CategoryWelding System
LanguageEnglish

Related product manuals