© Kemppi Oy 0615
MinarcTig
TM
180 15
EN
6. TECHNICAL DATA
The machine complies with the CE mark standards.
MinarTig
TM
180
Mains voltage 1 ~ 230 V ±15%, 50/60 Hz
Rated power TIG max6,7kVA(180A/17,2V)
MMA max7,0kVA(140A/25,6V)
Connection cable/fuse 3 × 2,5 mm
2
S–3mlongwith
Euro Schuko/16 A delayed
Load capacity 40 º C TIG 35%ED180A/17,2V
100%ED120A/14,8V
MMA 35 % ED 140 A/25,6 V
100 % ED 100 A/24 V
Welding range TIG 5A/10,2V–180A/17,2V
MMA 10A/20,4V–140A/25,6V
Open circuit voltage 95 V
Idle power TIG –
MMA 25 W
Powerfactoratmaxcurrent
TIG 0,62
MMA 0,63
Efciencyatmaxcurrent
TIG 0,75
MMA 0,81
Striking voltage 10 kV
Stick electrodes MMA Ø1,5–3,25mm
Externaldimensios
(L×W×H)
400x180x340
Weight 7,8kg
(8,4kgwithsupplycabel)
Temperature class H (B)
Degree of protection IP23C
Operating temperature
range
-20 °C...+40°C
Storage temperature range -40 °C...+60°C
Recommended generator > 7 kVA