22 – PROTIG 410 / 0537 © KEMPPI OY
10. TECHNICAL DATA
Protig 410
Working voltage (safety voltage) 50 VDC
Rated power 50 W
Max. load 60 % ED 400 A
100 % ED 310 A
Pressure endurance of gas hose 600 kPa max.
Connection of gas hose snap connector
Welding cable connectors DIX 70
Torch connection (adapter) Multi-function
Operation temperature range -20...+40 °C
Storage temperature range -40...+60 °C
Temperature class B (130 °C)
Degree of protection¹) IP 34
Dimensions length 615 mm
width 260 mm
height 400 mm
Weight 17 kg
The product meets conformity requirements for CE marking.
1)
IP 34 means that the device is protected against water coming from any direction, directly or
splashing.
Control panels
Main operations of Protig 410 panels TL and TX are in enclosed table.
TL 6271265 TX 6271266
Spark ignition yes yes
Contact ignition yes yes
2 function / 4 function torch operation yes yes
Fusion point timer -- yes
Pulsing -- yes
Minilog operation -- yes
Up-slope timer for current yes yes
Down-slope timer for current yes yes
Selectotig memory channels -- yes
Current display (digital) yes yes