FastMig Pulse
350, 450
CHANNEL
MENU
P65

Questions and Answers

  • A
    Anne HillJul 26, 2025
    What to do if my Kemppi Welding System machine won’t work?
    • H
      Holly MorrisJul 27, 2025
      If your Kemppi Welding System isn't working, try these steps: * Ensure the mains plug is properly connected. * Verify the mains power distribution is switched on. * Inspect the mains fuse or circuit breaker. * Confirm the power source 0/I switch is in the ON position. * Check the interconnection cable set and connectors between the power source and wire feed unit are correctly fastened. * Make sure the earth return lead is connected. * Verify the function panels are switched on by pressing the orange buttons on the top left.
  • B
    Brian McgeeAug 1, 2025
    Why is my Kemppi 350 producing dirty, poor quality welds?
    • T
      Tyler MorganAug 1, 2025
      A dirty, poor quality weld from your Kemppi Welding System can arise from several factors. You should: * Check the shielding gas supply. * Check and set the correct gas flow rate. * Ensure you're using the correct gas type for the application. * Verify the gun/electrode polarity. For example, when using Fe solid filler wire, the earth return should connect to the – pole, and the wire feed unit to the + pole connector. * Confirm the correct welding curve is selected. * Check the correct Channel (job) number is selected on the PF65 function panel. * Ensure the power supply isn't experiencing a phase down.
  • J
    Jennifer NicholsAug 8, 2025
    Why does my Kemppi Welding System have variable welding performance?
    • R
      Rachel SmithAug 8, 2025
      Inconsistent welding performance with your Kemppi Welding System can be caused by: * Incorrectly adjusted wire feed mechanism. * Incorrect drive rolls being fitted. * Wire spool overrun tension not correctly adjusted. * A blocked gun liner (replace if necessary). * The wrong gun liner fitted for the filler wire size and type. * Contact tip issues (size, type, and wear). * Gun overheating during application. * Loose cable connections and earth return clamp. * Incorrect welding parameter settings.
  • C
    Chelsea RamosAug 14, 2025
    What to do if the filler wire won’t feed in my Kemppi 350 Welding System?
    • J
      Jesse RobertsAug 14, 2025
      If the filler wire isn't feeding in your Kemppi Welding System, you can try the following: * Check the wire feed mechanism, ensuring pressure arms are closed and correctly adjusted. * Check the welding gun switch function. * Ensure the euro gun collar is correctly fastened to the euro block. * Inspect the gun liner for blockages. * Check the contact tip for proper size, type, and wear. * Try an alternative gun to rule out gun issues.
  • T
    Taylor StevensAug 19, 2025
    How to reduce high spatter volume with Kemppi Welding System?
    • M
      mcdonaldamyAug 19, 2025
      To address high spatter volume with your Kemppi Welding System: * Verify the welding parameter values. * Check inductance/Dynamics values. * Check the cable compensation value if long cables are fitted. * Check the gas type and flow. * Check the welding polarity and cable connections. * Check the filler material selection. * Confirm the correct welding curve is selected. * Check the correct Channel (job) number selection. * Check the filler wire delivery system. * Ensure the power supply has 3 x phases present.

Summary

INTRODUCTION

General

General information on the use, maintenance, and safety of Kemppi products.

About FastMig Pulse Products

Details on FastMig Pulse 350/450 CC/CV welding power sources and their applications.

INSTALLATION

Before Use and Environment

Checks before use and operating environment guidelines.

Machine Introduction and Positioning

Description of machine components and guidelines for placement.

Connecting Cables

Instructions for connecting various cables for welding operation.

Connecting to Mains Power

Procedure for connecting the power source to the mains supply.

Welding and Earth Return Cables

Recommendations for selecting suitable copper cables.

Interconnection with Wire Feeder

Guidance on using Kemppi interconnection cable sets.

OPERATION CONTROL

Main Switch and Pilot Lamps

Explanation of the main switch function and pilot lamp indications.

Cooling Fan Operation

Details on how the cooling fans operate during startup and after welding.

Manual Metal Arc Welding

Information on using the power source for MMA welding.

USING THE MACHINE

Arc Wizard P65 Interface Layout

Overview of the Arc Wizard P65 interface and its components.

Setup Panel P65 Quick Guide

Instructions for operating and setting up the P65 panel.

Welding Parameters

Details welding parameters for MIG, 1-MIG, Pulse MIG, and Double Pulse MIG.

Welding Functions

Details various welding functions like 2T/4T, HotStart, CraterFill.

Welding Software Delivery Profile

Information on available welding software options and part numbers.

Getting Started

Step-by-step guide for first-time users on language and channel setup.

BASIC TROUBLESHOOTING

Machine Wont Work

Common problems and their potential causes and checks for the MIG/MAG process.

Poor Weld Quality

Common problems and their potential causes and checks for the MIG/MAG process.

Variable Welding Performance

Common problems and their potential causes and checks for the MIG/MAG process.

Filler Wire Feed Issues

Common problems and their potential causes and checks for the MIG/MAG process.

High Spatter Volume

Common problems and their potential causes and checks for the MIG/MAG process.

OPERATION DISTURBANCES

Overload Protection

Explanation of the yellow thermal protection lamp and automatic cooling.

Control Fuses

Information about the 6.3 A delayed fuse for auxiliary devices.

Mains Voltage Issues

How the machine reacts to mains supply voltage fluctuations.

MAINTENANCE

Daily Maintenance

Routine checks of the welding gun, cables, and feed rolls.

Period Maintenance

Periodic checks and cleaning of machine internals, connectors, and cables.

Service Shop Maintenance

Overview of maintenance tasks performed by Kemppi Service Workshops.

DISPOSAL OF THE MACHINE

ORDERING NUMBERS

TECHNICAL DATA

Kemppi 350 Specifications

General IconGeneral
Duty Cycle at 40°C40% at 350 A
Welding ProcessMIG/MAG
Protection ClassIP23
StandardsIEC 60974-1
Power SupplyThree-phase