EN
WISEROOT / WISETHIN
WFSpeed
0.7 – 14 m/min * 0.05 m/min steps when WFSpeed < 5 m/min and
0.1 m/min steps when WFSpeed > 5 m/min
WFS-Max
Set the limit for maximum WFSpeed
WFS-Min
Set the limit for minimum WFSpeed
BaseCurrent
-50 ... +50 Adjusts the base current of the curve – the arc length –
within certain limits.
BaseCurrentMax
-50 ... +50 1% steps Set the limit for maximum “arc length”
BaseCurrentMin
-50 ... +50 1% steps Set the limit for minimum “arc length”
FormingPulse
-30 ... +30 Adjusts the forming pulse current of the curve in certain
limits. In other words, it controls arc pressure.
FormingPulseMax
-30 ... +30 1% steps Set the limit for maximum forming pulse current
FormingPulseMin
-30 ... +30 1% steps Set the limit for minimum forming pulse current
StartTime
-9 ... +9 Factory setting is 0 Set how long arc behaves like normal synergic MIG/
MAG prosess after the arc start. It gives heat for the arc
start.
StartVoltage
-30 ... +30 Factory setting is 0 Set the arc voltage which is used during StartTime.
In other words, it adjusts the length of the arc during
StartTime.
* Dierent welding curves may further restrict the value range further.
MMA PROCESSES
Current
14 – 350A/450A Welding current
CurrentMax
14 – 350A/450A Set the limit for maximum current value
CurrentMin
14 – 350A/450A Set the limit for minimum current value
ArcForce
-9 ... +9 Factory setting is 0 Controls the short circuit behaviour of the arc. The
lower the value the softer the arc is. The higher the
value the rougher the arc is.
4.3.2 Welding functions
OTHER PROCESSES
(In Edit Channel menu 3/6)
2T/4T
2T, 4T, MATCHLOG
or USER
Factory setting is USER =>
USER can freely choose the
switching logic
Set switching logic
HotStart
ON, OFF or USER Factory setting is USER =>
USER can freely choose is the
HotStart ON or OFF
HotStartLevel
-50 ... +100 % 1 % steps. Factory setting 40%
Hot 2T Time
0 – 9.9 s 0.1 s steps. Factory setting 1.2 s
CraterFill
ON, OFF, USER Factory setting is USER =>
USER can freely choose is the
CraterFill ON or OFF
CraterStart
10 – 250% Factory setting is 100% Set the level of the curve where the crater
lling will start
CraterFillEnd
10 – 250 %, not
higher than start
1 % steps. Factory setting 30% Set the level of the curve where the crater
lling will end.
12
FastMig Pulse 350, 450 / © Kemppi Oy / 1110